Certifications: ABSDNVEN 50121-4EN 55032/EN 55024FCC Part 15BGLKCLRLVD(EN 60950-1)NKKRoHSUL508
Technology: | |
Standards | IEEE 802.3 for
10BaseT IEEE 802.3u for 100BaseT(X) and 100Base FX IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseSX/LX/LHX/ZX/EZX IEEE 802.3x for Flow Control IEEE 802.1D for Spanning Tree Protocol IEEE 802.1w for Rapid STP IEEE 802.1Q for VLAN Tagging IEEE 802.1p for Class of Service IEEE 802.1X for Authentication IEEE 802.3ad for Port Trunk with LACP |
Protocols | IGMPv1/v2 device, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog, SNMP Inform, Modbus/TCP, IPv6 |
MIB | MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9 |
Flow Control | IEEE 802.3x flow control, back pressure flow control |
Switch Properties: | |
Priority Queues | 4 |
IGMP Groups | 256 |
Max. Number of Available VLANs | 64 |
VLAN ID Range | VID 1 to 4094 |
Interface: | |
RJ45 Ports | 10/100/1000BaseT(X) auto negotiation speed |
Fiber Port(s) | 100/1000BaseSFP slot |
Console | RS-232 (RJ45 connector) |
LED Indicators | PWR1, PWR2, FAULT, 10/100/1000M, MASTER, COUPLER |
DIP Switches | Turbo Ring, Master, Coupler, Reserve |
Alarm Contact | 2 relay outputs with current carrying capacity of 1A @ 24 VDC |
Digital Inputs | Two inputs with
the same ground, but electrically isolated from the electronics +13 to +30V for state "1" -30 to +3V for state "0" Max. input current: 8 mA |
Power Requirements: | |
Input Voltage | 12/24/48 VDC, 24 VAC (18 to 30 VAC), redundant dual inputs |
Overload Current Protection | Present |
Connection | Two removable 6-pin terminal blocks |
Reverse Polarity Protection | Present |
Physical Characteristics: | |
Enclosure | IP30 protection |
Housing | Metal case |
Dimensions | 87.1 x 135 x 107 mm (4.34 x 5.31 x 4.21 in) |
Installation | DIN-Rail Mounting, Wall Mounting (optional kit) |
Environmental Limits: | |
Operating Temperature | 0 to 60°C (32
to 140°F) -40 to 75°C (-40 to 167°F) for T models |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Agency Approvals: | |
EMI | FCC Part 15, CISPR (EN55022) class A |
EMS | EN61000-4-2 (ESD),
level 2 EN61000-4-3 (RS), level 3 EN61000-4-4 (EFT), level 2 EN61000-4-5 (Surge), level 3 EN61000-4-6 (CS), level 3 EN61000-4-8 EN61000-4-11 |
Safety | UL508 (Pending) EN60950-1 (Pending) |
Hazardous Location | UL/cUL Class I,
Division 2, Groups A, B, C,and D (Pending); ATEX Class I, Zone 2, Ex nC IIC (Pending) |
Shock | IEC60068-2-27 |
Freefall | IEC60068-2-32 |
Vibration | IEC60068-2-6 |
MTBF (meantime between failures) | 204,000 hrs Database: MIL-HDBK-217F, GB 25?C |
Maritime | DNV (Pending), GL (Pending) |
Warranty: | |
Warranty Period | 5 years |
Product Category | |
Product Category | Managed Switch |
Mechanical | |
Dimensions: WxHxD (mm) | 87.1mm x 135mm x 107mm |
Mounting | Din Rail |
IP level | IP30 |
Enclosure | Metal |
Data Rate and Number of Ports | |
Number of Ports | - |
Fast Ethernet, 10/100 Mbps | - |
Gigabit, 10/100/1000 Mbps | 9 |
Interface | |
Interface Type | 10/100/1000 Mbps RJ45, 10/100/100 Mbps SFP Combo |
Fiber connector | - |
PoE | - |
M12 Connector | - |
SFP | |
Digital I/O/Relay | Yes |
Console | - |
Bypass | - |
Modular Design | - |
Available Modular | - |
Power | |
Power Input Type | Redundant DC/DC Terminal Block |
Operating Supply Voltage | 12/24/48 VDC |
Power Consumption | 0.81 A @ 24V |
Reliability | |
Operating Temperature | 0C to 60C |
Redundancy and Backup Options | |
Redundancy Technology | Yes |
STP/RSTP/PSTP/MSTP | Yes |
Automatic Backup Configurator | Yes |
Certification | |
Certification | |
UL 508 (Industrial Control) | |
EN 50155 (Rail Industry) | |
EN 50121-4 (Rail Industry) | |
EN 50121-3-2 (Rail Industry) | |
NEMA TS2 (ITS) | |
IEC 61850-3 (Power Industry) | |
IEEE 1613 (Power Industry) | |
IEEE 1588PTP (Power Industry) | |
DNV.GL (Marine) | |
ABS.LR.NK (Marine) | |
C1D2 (Oil & Gas) | |
ATEX (Oil & Gas) | |
Network Management and Control | |
Layer Level Switching | L2 |
Modbus/TCP | Yes |
Ethernet/IP | Yes |
PROFINET | Yes |
SNMP/RMON | Yes |
LLDP | Yes |
DHCP | Yes |
IGMP Snooping/GMRP | Yes |
QoS | Yes |
VLAN 802.1Q | Yes |
IEEE 802.1X | Yes |
LACP (802.3ad) | |
Port Lock | - |
IPv6 | Yes |
Interface | |
Console Port | RS-232 (RJ45 connector) |
Digital Inputs | 2 inputs with the same ground, but electrically isolated from the electronics. • +13 to +30V for state “1” • -30 to +3V for state “0” • Max. input current: 8 mA |
DIP Switches | Turbo Ring, Master, Coupler, Reserve |
Fiber Ports | 100/1000BaseSFP slot |
LED Indicators | PWR1, PWR2, FAULT, 10/100/1000M, MSTR/HEAD, CPLR/TAIL |
Alarm Contact | 2 relay outputs with current carrying capacity of 1 A @ 24 VDC |
RJ45 Ports | 10/100/1000BaseT(X) auto negotiation speed |
Power Requirements | |
Overload Current Protection | Present |
Reverse Polarity Protection | Present |
Input Voltage | 12/24/48 VDC, redundant dual inputs |
Input Current | 0.81 A @ 24 V |
Connection | 2 removable 6-contact terminal blocks |
Technology | |
Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseX IEEE 802.3x for Flow Control IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1w for Rapid STP IEEE 802.1s for Multiple Spanning Tree Protocol IEEE 802.1Q for VLAN Tagging IEEE 802.1p for Class of Service IEEE 802.1X for Authentication IEEE 802.3ad for Port Trunk with LACP |
Flow Control | IEEE 802.3x flow control, back pressure flow control |
Protocols | IGMPv1/v2, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog, EtherNet/IP, Modbus/TCP, SNMP Inform, LLDP, IEEE 1588 PTP V2, IPv6, NTP Server/Client |
MIB | MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9 |
Environmental Limits | |
Operating Temperature | Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
MTBF (mean time between failures) | |
Time | 330,000 hrs |
Database | Telcordia (Bellcore), GB |
Physical Characteristics | |
Weight | 1510 g |
Dimensions | 87.1 × 135 × 107 mm (3.43 × 5.31 × 4.21 in) |
Installation | DIN-Rail mounting, wall mounting (with optional kit) |
Housing | Metal, IP30 protection |
Switch Properties | |
Priority Queues | 4 |
Max. Number of Available VLANs | 64 |
MAC Table Size | 8 K |
Packet Buffer Size | 1 Mbit |
VLAN ID Range | VID 1 to 4094 |
IGMP Groups | 256 |
Standards and Certifications | |
EMI | FCC Part 15 Subpart B Class A, EN 55022 Class A |
Safety | UL 508, EN 60950-1 |
Rail Traffic | EN 50121-4 |
Note | Please check Moxa’s website for the most up-to-date certification status. |
Shock | IEC 60068-2-27 |
Vibration | IEC 60068-2-6 |
EMS | EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3, EN 61000-4-6 (CS) Level 3, EN61000-4-8 |
Freefall | IEC 60068-2-32 |
Marine | DNV, GL, LR, ABS, NK |
Warranty | |
Warranty Period | 5 years |
Details | See www.moxa.com/warranty |