Improve system efficiency via real-time data acquisition
Unlike
traditional passive remote I/O, Active Remote I/O provides Active I/O
messaging that can send message over Ethernet, TCP/IP network on I/O
input status changes or meets certain condition, the message is sent to
host computer. Communication between the host computer and Active
Remote I/O device is concise and efficient. In addition, the message
delivery time is 20 times faster than traditional SCADA systems (50 ms
compared to 1 sec).
No programming! Hassle-free Click&Go™ logic control
Click&Go™
logic is the key to make ioLogik E2000 series become an intelligent
remote I/O. Click&Go™ logic lets you decide when to send I/O data,
and what to say to host computers for simple alarm control and
messaging.
As opposed to using C-language or PLC-ladder, a
person who understands basic logic concepts can do the configuration
themselves, and easily finish their projects. Unlike passive remote I/O
architecture, you can integrate Active Remote I/O’s input signals into
one event to be an integrated message, and set up local output control
at the same time. The unique Click&Go™ logic is a patent pending
technology developed by Moxa.
Unique LCD Display Module for on-site configuration
ioLogik
E2000 series Active Remote I/O provides an optional LCD display module
for on-site management and configuration. The unique display module can
display network and I/O settings, e.g. analog input value, digital
input counter value. The IP, netmask address can be set locally without
carrying a PC.
Independent Configuration for Multi-functional DI and DO
points
Each digital input can be configured independently for DI or Event
Counter mode, and each digital output can be independently configured
for DO or Pulse Output mode.
Typical Application
Features
|
Actively transfer I/O data in real-time over Ethernet |
|
|
Easy-to-use Click&Go™ Logic for local output control
and messaging |
|
|
12-point 24VDC digital input with DI/Event counter |
|
8
points 24VDC digital output as pulse output |
|
10/100Mbps
Ethernet with Modbus/TCP protocol Connecting up to 10 hosts |
|
SNMP
to I/O mapping that works with Network Management System |
|
Quick
programming library for VB, VC, BCB |
|
Specifications
LAN |
|
|
|
1.5 KV magnetic isolation |
|
|
|
Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP (MIB for I/O
and Network), HTTP, SNTP,Active I/O Messaging, IP filtering |
|
|
|
|
Serial |
|
RS-485 (2-wire): Data+, Data-, GND |
|
|
|
15 KV ESD for all signals |
|
|
|
|
|
Serial Communication Parameters |
|
|
|
Power Requirements |
|
24 VDC nominal, 12 to 48 VDC |
|
|
|
|
|
24 VDC nominal, up to 48 VDC |
|
|
|
|
Mechanical Specifications |
|
|
Environmental |
|
-10 to 60°C (14 to 140°F), 5 to 95% RH |
|
|
|
-40 to 85°C (-40 to 185°F), 5 to 95%RH |
|
|
|
|
|
|
Digital Input |
|
|
|
|
DI or Event Counter (up to 900 Hz) |
|
|
|
Logic 0: short to GND, Logic 1: open |
|
|
|
Logic 0: 0 to 3 VDC,
Logic 1: 10 to 30 VDC (DI COM to DI) |
|
|
|
|
|
|
|
|
|
Digital Output |
|
|
|
|
DO or Pulse output (up to 1 KHz) |
|
|
|
|
|
|
|
|
|
Over temperature shutdown: Min. 170°C
Over current limit: typ. 750 mA/channel |
|
|
|
|
|
Agency Approvals |
|
|
FCC Part 15, CISPR (EN55022) Class A |
|
|
|
IEC61000-4-2 (ESD), level 2/3
IEC61000-4-3 (RS), level 2
IEC61000-4-4 (EFT), level 2
IEC61000-4-5 (Surge), level 3
IEC61000-4-6 (CS), level 2
IEC61000-4-8 (PM), level 1
IEC61000-4-11 (Dip) |
|
|
|
|
|
|
|
|
|
|
|
|
Specification
Power Requirements |
Power Consumption |
203 mA @ 24 VDC |
Power Input |
24 VDC nominal, 12 to 36 VDC |
Serial Communication Parameters |
Flow Control |
None |
Protocol |
Modbus/RTU |
Data Bits |
8 |
Parity |
None |
Stop Bits |
1 |
Baudrate |
1200 to 115200 bps |
Inputs and Outputs |
Digital Inputs |
12 channels |
Digital Outputs |
8 channels |
LAN |
Protection |
1.5 KV magnetic isolation |
Ethernet |
1 x 10/100 Mbps, RJ45 |
Protocols |
Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP, HTTP, CGI, SNTP |
Digital Input |
Isolation |
3K VDC or 2K Vrms |
Common Type |
12 points per COM |
Over-voltage Protection |
36 VDC |
Digital Filtering Time Interval |
Software selectable |
Dry Contact |
• On: short to GND • Off: open |
Wet Contact |
NPN (Source Type) • On: 0 to 3 VDC • Off: 10 to 30 VDC |
Counter Frequency |
900 Hz |
I/O Mode |
DI or Event Counter |
Sensor Type |
Wet Contact (NPN), Dry Contact |
Environmental Limits |
Operating Temperature |
-10 to 60°C (14 to 140°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
Physical Characteristics |
Weight |
under 250 g |
Dimensions |
115 x 79 x 45.6 mm (4.53 x 3.11 x 1.80 in) |
Wiring |
I/O cable max. 14 AWG |
Standards and Certifications |
EMI |
FCC Part 15 Subpart B Class A, EN 55022 Class A |
Safety |
UL 508 |
Shock |
IEC 60068-2-27 |
Vibration |
IEC 60068-2-6 |
EMS |
IEC 61000-4, IEC 61000-6 |
Freefall |
IEC 60068-2-32 |
Digital Output |
Type |
Sink |
Isolation |
3K VDC or 2K Vrms |
Pulse Output Frequency |
1 kHz |
Over-temperature Shutdown |
175°C (min.) |
Over-voltage Protection |
45 VDC |
Current Rating |
200 mA per channel |
I/O Mode |
DO or Pulse Output |
Over-current Protection |
2.6 A (4 channels @ 650 mA) |
Serial Communication |
Interface |
RS-485-2w: Data+, Data-, GND |
Serial Line Protection |
15 KV ESD for all signals |
MTBF (mean time between failure) |
Time |
213,673 hrs |
Database |
Telcordia (Bellcore) |
Warranty |
Warranty Period |
5 years |
Details |
See www.moxa.com/warranty |
$68.00
Stock: 2