TRIPP LITE 

Tripp Lite SmartPro 1200XLHG UPS


Mfg Part Number:  SMART1200XLHG  
Image may not reflect the actual item.
Price: $869.28 + Free Shipping
Quantity:
In Stock: 44
Last Updated: Mar 28, 2024
No Sales Tax except these states
, PO and Wire.
Main Specification
General Information
ManufacturerTripp Lite
Manufacturer Part NumberSMART1200XLHG
Manufacturer Website Addresshttp://www.tripplite.com
Brand NameTripp Lite
Product LineSmartPro
Product NameSmartPro 1200XLHG UPS
Product TypeLine-interactive UPS
Technical Information
Plug/Connector TypeNEMA 5-15P
Receptacles4 x NEMA 5-15R
Cord Length6 ft
Power Description
Load Capacity (VA)1 kVA
Load Capacity (Watt)750 W
Input Voltage110 V AC
Output Voltage120 V AC
Management
Network ManagementSNMP Manageable
AlarmLow Battery
AlarmOn Battery
AlarmOverload
Controls/Indicators
Status IndicatorsIncludes 5 front-panel indicator LEDs to show battery charge level, AC line voltage levels, automatic voltage regulation status, UPS load level and replace battery warning
Interfaces/Ports
USBYes
Battery Information
Battery ChemistrySealed Lead Acid
Backup/Run Time (Full Load)16 Minute
Backup/Run Time (Half Load)34 Minute
Battery Life6 Year
Maximum Battery Recharge Time4 Hour
Hot SwappableYes
Environmental Conditions
Temperature104°F (40°C)
Physical Characteristics
Height12.8"
Width7.5"
Depth9"
Form FactorTower
Weight (Approximate)44.60 lb
Miscellaneous
Package Contents
  • SmartPro 1200XLHG UPS
  • SMART 1200XLHG Medical Grade Tower UPS System
  • PowerAlert Software and cabling
  • Warranty information
  • Instruction manual
Additional Information
  • Ideal UPS protection for applications in medical patient-care areas where UL 2601-1 listed medical electrical equipment is required
  • Maintains less than 300 microamps leakage current for UPS and all connected equipment
  • Built-in isolation transformer with faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes
  • Provides connected equipment with continuous power during short and long duration loss of commercial power
  • Expandable runtime is available with the addition of one or more external battery packs (part# BP36V27)
  • Line-interactive voltage regulation corrects brownouts and overvoltages from 81 to 143 volts back to usable 120V output levels, without using battery power
  • Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections
  • Full line isolation prevents shock potential and operational problems in sensitive electronic equipment
  • Resistant to electrostatic discharge
  • Supports loads up to 1000VA / 750 watts
  • 34 minutes half load runtime (500VA/375 watts), 16 minutes full load runtime (1000VA/750 watts)
  • 4 protected hospital-grade outlets; 6-ft. cord
  • 1-RS-232 and 1-USB serial port for network interface; SNMP compatible
  • SNMP compatible with separate purchase SNMPWEBSOLO ethernet adapter accessory
  • Complete surge protection, line isolation and EMI/RFI noise filtering
  • 2 year product warranty
  • PowerAlert unattended shutdown software and complete cabling included
  • 5 diagnostic LEDs indicate AC present, on battery, voltage correction, overload & battery low/replace
  • Battery replacement door
  • Back panel grounding lug
Certifications & StandardsUL1778 (USA, Series AGSM1200PSR3HG), UL2601-1 (Medical), cUL (Canada), FCC Class A (emissions), Conforms to IEEE 587 / ANSI C62.41 specifications
Warranty
Limited Warranty2 Year
General Information
Power Rating 1000 VA
Output Voltage Rating 120 V
Number of Outputs 4
Runtime-Full Load 16 min
Runtime-Half Load 34 min
Tripp Lite's SMART 1200XLHG offers medical-grade UPS protection with built-in line-interactive voltage regulation, expandable battery runtime and intelligent monitoring with unattended shutdown capability. UL 60601-1 listed as medical electrical equipment with less than 300 microamps leakage current for the UPS and all connected equipment. Built-in isolation transformer with Faraday shield offers full line isolation and removes common mode noise while maintaining full AC surge suppression in all modes. Includes high quality hospital-grade plug and outlets. Resistant to electrostatic discharge. 1000VA power handling capacity supports computers, internetworking equipment and other critical loads during commercial power failures. External battery connector allows configuration for up to several hours of runtime during power failures by adding one or more external battery packs (part# BP36V27). Line interactive voltage regulation corrects brownouts as low as 81V and overvoltages as high as 143V back to normal 120V levels, saving battery reserves for use only during complete power failures. Includes diagnostic LEDs and 2 built-in communications ports (1 USB, 1 DB9) that work with included PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications.

Features:

  • Ideal UPS protection for applications in medical patient-care areas where UL 60601-1 listed medical electrical equipment is required

  • Maintains less than 300 microamps leakage current for UPS and all connected equipment

  • Built-in isolation transformer with faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes

  • Provides connected equipment with continuous power during short and long duration loss of commercial power

  • Expandable runtime is available with the addition of one or more external battery packs (part# BP36V27)

  • Line-interactive voltage regulation corrects brownouts and overvoltages from 81 to 143 volts back to usable 120V output levels, without using battery power

  • Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections

  • Full line isolation prevents shock potential and operational problems in sensitive electronic equipment

  • Resistant to electrostatic discharge

  • Supports loads up to 1000VA/750W

  • 34 min. half-load runtime (500VA/375W), 16 min. full load runtime (1000VA/750W)

  • 4 protected hospital-grade outlets; 6-ft. cord

  • USB and DB9 communication ports

  • PowerAlert unattended shutdown software and complete cabling included

  • Complete surge protection, line isolation and EMI/RFI noise filtering

  • 5 diagnostic LEDs indicate AC present, on battery, voltage correction, overload & battery low/replace

  • Battery replacement door and back panel grounding lug

  • 2-year product warranty
Typical Applications:

UL 60601-1 listed UPS provides ultimate safety and reliability for patient point of care solutions, telemedicine, nurse's stations, wireless communications systems, electronic prescribing applications, medical imaging and mission critical equipment. Not recommended for life support applications.

Specifications:

SYSTEM OVERVIEW
System overview:
Medical Grade tower UPS system includes built in isolation transformer with faraday shield, line interactive voltage regulation. AC surge suppression, RS-232 & USB monitoring ports with complete software and cabling, plus hospital-grade plug and outlets. Runtime is expandable via separate purchase BP36V27 external battery packs. UL 60601-1 listed as medical electrical equipment with less than 300 microamps combined leakage current for UPS and connected loads.
Voltage compatibility:
120V AC
Frequency compatibility:
60 Hz
OUTPUT
Output volt amp capacity (VA):
1000
Output watt capacity (watts):
750
Output nominal voltage:
120V AC
Output voltage regulation:
LINE MODE: Sine wave line voltage 120V (-18% / +8%)
BATTERY MODE: PWM sine wave output 115V +/-5%
Output frequency regulation:
LINE MODE: Passes line frequency of 60Hz +/-10%
BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz
Outlet quantity / type:
4 NEMA 5-15R HG
Overload protection:
Resettable circuit breaker
INPUT
Maximum input amps:
9.2A / 860 watts
Input connection type:
NEMA 5-15P HG
Input cord length:
6 ft., 14 gauge
Recommended electrical service:
15A 120V
BATTERY
Full load runtime:
16 min. (1000VA)
Half load runtime:
34 min. (500VA)
Expandable battery runtime:
Supports extended runtime with optional BP36V27 external battery pack (multi-pack compatible)
DC system voltage:
36V DC
Typical battery lifespan:
3-6 years, depending on usage
Battery recharge rate:
2-4 hours to 90%
VOLTAGE REGULATION
Voltage regulation description:
Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 81 to 143V AC.
Overvoltage correction:
Input voltages between 126 and 143V AC are reduced by 9%
Direct pass through:
Input voltages between 105 and 125V AC are passed through unchanged
Brownout correction:
Input voltages between 96 and 106V AC are boosted by 10%
Severe brownout correction:
Input voltages between 81 and 95V AC are boosted by 21%
LEDS ALARMS & SWITCHES
Front panel LEDs:
Yes, includes 5 front-panel indicator LEDs to show battery charge level, AC line voltage levels, automatic voltage regulation status, UPS load level and replace battery warning
Alarms:
3 function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone)
Switches:
Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions
SURGE / NOISE SUPPRESSION
AC surge suppression:
480 joules
AC suppression response time:
Instantaneous
EMI / RFI AC noise suppression:
Yes
PHYSICAL
Shipping weight (lbs):
49.2
Shipping weight (kg):
22.4
Unit weight (lbs):
45.2
Unit weight (kg):
20.5
Unit Dimensions (HWD/in):
12.5 x 7.5 x 9.5
Unit Dimensions (HWD/cm):
31.75 x 19.1 x 24.2
Shipping Dimensions (HWD/in):
18.25 x 11.75 x 13.5
Shipping Dimensions (HWD/cm):
46.4 x 29.9 x 34.3
Material of construction:
PVC
Form factors supported:
Tower
Cooling method:
UPS cooling via rear-exit fan
Battery Access:
Battery access door allows hot swap battery replacement without powering connected equipment off
ENVIRONMENTAL
Operating Temperature:
+32 to +104 degrees Fahrenheit
0 to +40 degrees Celsius
Storage Temperature:
+5 to +122 degrees Fahrenheit
-15 to +50 degrees Celsius
Relative Humidity:
0 to 95%, non-condensing
COMMUNICATIONS
Network monitoring port:
Includes 2 built-in monitoring ports, 1 USB & 1 DB9
Software and cabling included:
PowerAlert UPS monitoring software is included on CD-ROM for all common network and standalone operating systems. Ships with 2 cables, 1-USB to USB & 1-DB9 to DB9
LINE / BATTERY TRANSFER
Transfer time from line power to battery mode:
2-4 milliseconds
Low voltage transfer to battery power:
81V (resets to line power as voltage increases to 85V)
High voltage transfer to battery power:
143V (resets to line power as voltage decreases to 139V)
CERTIFICATIONS
Certifications:
UL1778 (USA, Series AGSM1200PSR3HG), UL 60601-1 (Medical), cUL (Canada), Class A (Emissions)
WARRANTY
Optional coverage:
3-year, 5-year, next day and on-site warranty coverage available in many areas; contact Tripp Lite
Product warranty:
2 year product warranty
SPECIAL FEATURES
Cold Start:
Yes, inverter can be cold started to enable temporary AC output during a power failure
Appearance:
Attractive gray tower UPS




Connector Adapters

Connector Cables

PDUs

Patch Panels

Services

Surge Suppressors/Protectors

UPS Batteries

[1027] [True] [Yes] [No] [Yes]

nextwarehouse.com has a Shopper Approved rating of 4.6/5 based on 29303 ratings and reviews.